Shell
|
Industrial fiber reinforced polycarbonate
|
IP grade
|
IP65
|
Weight
|
Appr. 710g
|
Dimension
|
Length 166mm
|
Height 88mm(not include anti-shock pad)
|
Width 131mm(not include antenna)
|
Antenna
|
External, TNC connector
|
Input
|
1 line 0/3.3-36 VDC analog output limited signal
4 lines programmable analog quantity or switching value input(analog quantity range 0-5 VDC, switching value range 0/3.3-36 VDC)
|
Output
|
4 programmable PWM/motor drive/switching value output
1 MC main relay output 12-24VDC, Max. load 10A
6 lines programmable switching value output 12/24 VDC, 8A(originated from main replay output)
3 lines programmable switching value output 12/24 VDC, 8A(external power supply, can be switched at GND end)
1+5VDC, 500mA PPTC power output
|
Fuse
|
20A blade shape fuse
|
Power supply
|
12/24 VDC +/-50%
|
LED diagnostic display
|
Power supply/operation, signal receive, emergency stop fault, signal type
|
Frequency range
|
419,429,434,447,458,480,868,1216 MHz
|
Wireless technology
|
Microprocessor controls logic synthesizer, AUTX frequency modulation function is optional, AUTX multi point frequency hopping function
|
Control distance
|
Appr. 100m
|
Safety technology
|
20 programmable address code, up to 100 million combination
|
Active and passive emergency stop function
|
Security check code
|
Comply with 3 kinds of safety standard
|
Working temperature range
|
-25°C~+70°C (-13°F ~ +158°F)
|
Operation humidity range
|
0-97%,Max. anti-coagulation
|
Response time
|
less than 100ms
|
Baud rate
|
9600bps
|
Standard configuration
|
Pocket PC and H-link all computer programmable
Equipped with standard industrial quick coupling
RS232 wire control function
Analog quantiy and digital quantity automatically saved
1 received can be maximumly matched with 4 receiver
Anti-shock pad
|