Shell
|
Industrial fiber reinforced polycarbonate
|
IP grade
|
IP65
|
Weight
|
Appr. 710g
|
Dimension
|
Length 166mm
|
Height 88mm(not include anti-shock pad)
|
Width 131mm(not include antenna)
|
Antenna
|
External, TNC connector
|
I/O communication interface
|
1*CAN communication interface(RX ES-CAN)
1*Profibus DP communication interface(RX ES-Profi)
|
Input
|
6 lines digital control signal input 6-36VDC
|
Output
|
1 seperate power normal open emergency stop relay 8A, up to 30 VDC or 240 VAC
|
LED diagnostic display
|
Power/operation guidance, signal receive, emergency stop, CAN/Proi communication status
|
Frequency range
|
419,429,434,447,458,480,868,1216 MHz
|
Wireless technology
|
Microprocessor controls logic synthesizer, AUTX frequency modulation function is optional, AUTX multi point frequency hopping function
|
Control distance
|
Appr. 100m
|
Safety technology
|
20 programmable address code, up to 100 million combination
|
Active and passive emergency stop function
|
Security check code
|
Working temperature range
|
-25°C~+70°C (-13°F ~ +158°F)
|
Operation humidity range
|
0-97%,Max. anti-coagulation
|
Response time
|
less than 100ms
|
Baud rate
|
9600bps
|
Standard configuration
|
Equipped with standard industrial quick coupling
1 receiver can be matched with maximumly 16 transmitter
Anti-shock pad
Note: RX ES-Proi receiver not include Profibus D-Sub connector
|
Communication protocal
|
Hetronic standard CANopen
|
Hetronic standard Profibus DP
|
J1939
|
Parker IQAN
|
CAN Kindom
|
DeviceNet
|
Customized communication protocal
|